PA612 33% Glass Fiber Toughened Material Data Sheet

PA612 33% Glass Fiber Toughened (Polyamide 612) Material Data Sheet

PA612 33% Glass Fiber Toughened Overview

PA612 33% glass fiber toughened is a grade of polyamide 612 (PA612, nylon 612), designated Polyamide (Nylon) (Type 612, 33% Glass Fiber, Toughened). This PA612 33% glass fiber toughened material data sheet covers its designation and tradenames, composition, physical, mechanical, thermal, electrical and magnetic properties, and water absorption, processing properties and durability. Looking for PA612 parts from Turkey (Türkiye)? Modulus Metal manufactures CNC machined PA612 parts in-house and inspects them before shipment.

PA612 33% Glass Fiber Toughened Designation

Polyamide (Nylon) (Type 612, 33% Glass Fiber, Toughened)
TradenamesAkromid, Edgetek, Grilamid, Technyl, Ultramid, Zytel

PA612 33% Glass Fiber Toughened Typical uses

Mechanical parts, zips, filaments, coverings and coatings requiring abrasion resistance.

PA612 33% Glass Fiber Toughened Composition detail

Polymer52–64%
Impact modifier3–15%
Glass (fiber)33  %

PA612 33% Glass Fiber Toughened Physical properties

Density1.25–1.27g/cm3

PA612 33% Glass Fiber Toughened Mechanical properties

Young’s modulus5.86–7.31GPa
Specific stiffness4.65–5.8MN.m/kg
Yield strength (elastic limit)114–142MPa
Tensile strength115–141MPa
Specific strength90.5–113kN.m/kg
Elongation2.64–3.8% strain
Elongation at yield2.22–4.22% strain
Compressive modulus6.26–6.92GPa
Compressive strength146–162MPa
Flexural modulus5.27–6.31GPa
Flexural strength (modulus of rupture)171–209MPa
Shear modulus2.34–2.46GPa
Shear strength69.3–84.6MPa
Bulk modulus8.22–9.08GPa
Poisson’s ratio0.358–0.373 
Shape factor5.39
Hardness – Vickers37–40HV
Hardness – Rockwell M163–181 
Hardness – Rockwell R163–181 
Hardness – Shore D93–97 
Elastic stored energy (springs)982–1560kJ/m3
Fatigue strength at 10^7 cycles48.7–53.9MPa

PA612 33% Glass Fiber Toughened Impact & fracture properties

Fracture toughness4.48–4.95MPa.m0.5
Toughness (G)2.93–3.91kJ/m2
Impact strength, notched 23 °C10.2–19.8kJ/m2
Impact strength, notched -30 °C6.3–13.7kJ/m2
Impact strength, unnotched 23 °C64.8–95.2kJ/m2
Impact strength, unnotched -30 °C42–63kJ/m2

PA612 33% Glass Fiber Toughened Thermal properties

Melting point195–217°C
Glass temperature40–52°C
Heat deflection temperature 0.45MPa199–247°C
Heat deflection temperature 1.8MPa174–220°C
Maximum service temperature47–67°C
Minimum service temperature-127–-107°C
Thermal conductivity0.396–0.412W/m.°C
Specific heat capacity1470–1530J/kg.°C
Thermal expansion coefficient57.6–58.7µstrain/°C
Thermal shock resistance287–389°C
Thermal distortion resistance0.00679–0.0071MW/m

PA612 33% Glass Fiber Toughened Electrical properties

Electrical resistivity2.73e21–6.83e22µohm.cm
Electrical conductivity2.52e-21–6.32e-20%IACS
Dielectric constant (relative permittivity)4.57–6.44 
Dissipation factor (dielectric loss tangent)0.0223–0.0587 
Dielectric strength (dielectric breakdown)20.4–34.7MV/m
Comparative tracking index600  V

PA612 33% Glass Fiber Toughened Magnetic properties

Magnetic typeNon-magnetic

PA612 33% Glass Fiber Toughened Optical, aesthetic and acoustic properties

TransparencyOpaque
Acoustic velocity2150–2410m/s
Mechanical loss coefficient (tan delta)0.0104–0.0115 

PA612 33% Glass Fiber Toughened Absorption & permeability

Water absorption @ 24 hrs0.38–0.61%
Water absorption @ sat1.7–2.2%
Humidity absorption @ sat0.7–0.95%

PA612 33% Glass Fiber Toughened Processing properties

Polymer injection moldingExcellent
Polymer extrusionLimited use
Polymer thermoformingLimited use
Linear mold shrinkage0.2 – 0.5 %
Melt temperature212 – 293 °C
Mold temperature30 – 60 °C
Molding pressure range27.5 – 138 MPa

PA612 33% Glass Fiber Toughened Durability

Water (fresh)Acceptable
Water (salt)Acceptable
Weak acidsUnacceptable
Strong acidsUnacceptable
Weak alkalisAcceptable
Strong alkalisAcceptable
Organic solventsAcceptable
Oxidation at 500CUnacceptable
UV radiation (sunlight)Fair
FlammabilitySlow-burning