ISO 2768-1 and ISO 2768-2 Tolerances

ISO 2768-1 General tolerances

Part 1: Tolerances for linear and angular dimensions without individual tolerance indications

Table 1 — Permissible deviations for linear dimensions except for broken edges (external radii and chamfer heights, see Table 2) – Values in millimeters
Tolerance classPermissible deviations for basic size range
DesignationDescription0.5a
up to 3
over 3
up to
6
over
6
up to 30
over 30
up to 120
over 120
up to 400
over 400
up to 1000
over 1000
up to 2000
over
2000
up to 4000
ffine± 0.05± 0.05± 0.1± 0.15± 0.2± 0.3± 0.5
mmedium± 0.1± 0.1± 0.2± 0.3± 0.5± 0.8± 1.2± 2
ccoarse± 0.2± 0.3± 0.5± 0.8± 1.2± 2± 3± 4
vvery coarse± 0.5± 1± 1.5± 2.5± 4± 6± 8
aFor nominal sizes below 0.5 mm. the deviations shall be indicated adjacent to the relevant nominal size(s). 
Table 2 — Permissible deviations for broken edges (external radii and chamfer heights) – Values in millimeters
Tolerance classPermissible deviations for basic size range
DesignationDescription0.5a  up to 3over 3 up to 6over 6
ffine± 0.2± 0.5± 1
mmedium
ccoarse± 0.4± 1± 2
vvery coarse
aFor nominal sizes below 0.5 mm. the deviations shall be indicated adjacent to the relevant nominal size(s).
Table 3 — Permissible deviations of angular dimensions
Tolerance classPermissible deviations for ranges of lengths, in millimeters, of the shorter side of the angle concerned
DesignationDescriptionup to 10over 10 up to 50over 50 up to 120over 120 up to 400over 400
ffine± 1°± 0°30′± 0°20′± 0°10′± 0°5′
mmedium
ccoarse± 1°30′± 1°± 0°30′± 0°15′± 0°10′
vvery coarse± 3°± 2°± 1°± 0°30′± 0°20′

ISO 2768-2 General tolerances

Part 2: Geometrical tolerances for features without individual tolerance indications

Table 1 — General tolerances on straightness and flatness – Values in millimeters
Tolerance classStraightness and flatness tolerances for ranges of nominal lengths
up to 10over 10 up to 30over 30
up to 100
over
100 up
to 300
over
300 up
to 1000
over
1000 up
to 3000
H0.020.050.10.20.30.4
K0.050.10.20.40.60.8
L0.10.20.40.81.21.6
Table 2 — General tolerances on perpendicularity – Values in millimetres
Tolerance classPerpendicularity tolerances for ranges of nominal lengths of the shorter side
up to 100over 100 up to 300over 300 up to 1000over 1000
up to 3000
H0.20.30.40.5
K0.40.60.81
L0.61.01.52
Table 3 — General tolerances on symmetry – Values in millimetres
Tolerance classSymmetry tolerances for ranges of nominal lengths
up to 100over 100
up to 300
over 300
up to 1000
over 1000
up to 3000
H0.5
K0.60.81
L0.611.52
Table 4 — General tolerances on circular run-out – Values in millimetres
Tolerance classCircular run-out tolerances
H0.1
K0.2
L0.5
ISO 2768 Tolerances